當(dāng)前位置:技成首頁 > 文章中心 > 技成百科 > STOP due to: STOP caused by priority class system

STOP due to: STOP caused by priority class system

劉玉蓉 發(fā)布于2014-10-24 17:38 3 0 標(biāo)簽:

Event 290 of 500:  Event ID 16# 4302
Mode transition from STARTUP to RUN
Startup information: 
- Time for time stamp at the last backed up power on
- Single processor operation
Current/last startup type:
- Warm restart triggered via MPI; last power on backed up
Permissibility of certain startup types: 
- Manual warm restart permitted
- Automatic warm restart permitted
Last valid operation or setting of automatic startup type at power on:
- Warm restart triggered via MPI; last power on backed up
Previous operating mode: STARTUP (warm restart)
Requested operating mode: RUN
Incoming event
02:09:25.073 AM  04/18/1994


Event 291 of 500:  Event ID 16# 1381
Request for manual warm restart 
STOP due to: STOP caused by priority class system
Startup information:
- Startup without modified system configuration 
- No difference between setpoint and actual configuration
- Time for time stamp at the last backed up power on
- Single processor operation
Current/last startup type:
- Warm restart triggered via MPI; last power on backed up
Permissibility of certain startup types: 
- Manual warm restart permitted
- Automatic warm restart permitted
Last valid operation or setting of automatic startup type at power on:
- Warm restart triggered via MPI; last power on backed up 
Requested OB: Startup OB (OB100)
Priority class: 27
Incoming event
02:09:25.072 AM  04/18/1994

Event 292 of 500:  Event ID 16# 4301
Mode transition from STOP to STARTUP 
STOP due to: STOP caused by priority class system
Startup information: 
- Time for time stamp at the last backed up power on
- Single processor operation
Current/last startup type:
- Warm restart triggered via MPI; last power on backed up
Permissibility of certain startup types: 
- Manual warm restart permitted
- Automatic warm restart permitted
Last valid operation or setting of the automatic startup type at power on:
- Warm restart triggered via MPI; last power on backed up
Previous operating mode: STOP (internal)
Requested operating mode: STARTUP (warm restart)
Incoming event
02:09:24.981 AM  04/18/1994

Event 294 of 500:  Event ID 16# 5371
Distributed I/Os: End of the synchronization with a DP master/IO controller   on slot    2 
Number of distributed stations:   1
Incoming event
02:09:24.295 AM  04/18/1994


Event 295 of 500:  Event ID 16# 4541
STOP caused by priority class system
Event: Cycle time exceeded
OB number: Timing error OB (OB80)
Priority class:   26
Previous operating mode: RUN
Requested operating mode: STOP (internal)
Internal error, Incoming event
02:02:35.109 AM  04/18/1994

佳答案

在診斷信息描述中調(diào)用了OB80。
OB80 :時間故障。可能的原因:
這樣的故障包括: 循環(huán)時間超出、執(zhí)行OB 時應(yīng)答故障、向前移動時間以致于躍過了OB 的啟動時間、CiR 后恢復(fù)RUN 方式。如果,例如,當(dāng)循環(huán)中斷OB 仍在執(zhí)行前一次調(diào)用時,該OB 塊的啟動事件發(fā)生,操作系統(tǒng)調(diào)用OB80。如果OB80 未編程,CPU 變?yōu)镾TOP 方式。您可以使用SFC39 至42 封鎖或延時和再使能時間故障OB。
注意:如果在同一個掃描周期中由于掃描時間超出OB80 被調(diào)用兩次,CPU 就變?yōu)镾TOP 方式。您可以通過在程序中適當(dāng)?shù)奈恢谜{(diào)用SFC43“RE_TRIGR ”來避免這種情況。

參見:

詳見《組織塊使用說明》下載:
https://218.93.112.166/ec/C23/dl/xxzl/%E7%BB%84%E7%BB%87%E5%9D%97%E4%BD%BF%E7%94%A8%E8%AF%B4%E6%98%8E.pdf

若有收獲,就點個贊吧!

文章來源于網(wǎng)絡(luò)及文獻如有侵權(quán)請聯(lián)系站長