wincc OPC通訊 simatic net配置問題

劉玉蓉 發(fā)布于2014-10-17 16:52 4 0 標(biāo)簽:

診斷提示的問題如下:
================================ 09/21/2011 9:08:25 AM ================================
PLC Download to Current Project Selected Stations (288:91): With the set interface configuration, communication in STEP7 is not possible.
PLC Download to Current Project Selected Stations (288:47): Unable to reach the module Stationmanager via the online interface.
PLC Download to Current Project Selected Stations (13:4711): Unable to establish connection to module Stationmanager (Index 125) in station S7200.
PLC Download to Current Project Selected Stations (33:17074): Online: Driver configuration error or invalid registry parameter.
PLC Download to Current Project Selected Stations (13:4708): Unable to establish the connection to the module Stationmanager (Index 125) in station S7200.

Do you want to continue downloading without this module?
PLC Download to Current Project Selected Stations (33:17074): Online: Driver configuration error or invalid registry parameter.
PLC Download to Current Project Selected Stations (13:4708): Unable to establish the connection to the module OPC Server (Index 1) in station S7200.

Do you want to continue downloading without this module?

下面圖中總是顯示網(wǎng)卡是STOP狀態(tài),很納悶,希望各位高手幫幫忙?。?/p>

問題補(bǔ)充:
PLC Download to Current Project Selected Stations (13:4711): Unable to establish connection to module Stationmanager (Index 125) in station S7200.
這個(gè)是什么問題?槽125是起什么作用的?


圖片說明: 1,錯(cuò)誤提示1   2,錯(cuò)誤提示2   3,槽號(hào)125狀態(tài)   4,station configuration editor配置  

佳答案

station configuration editor配置 上開看組態(tài)沒有完成 :
1 ,opc sever的狀態(tài)是“X”。
2,IE general也是停止沒有連上。
組態(tài)設(shè)置都正確,下載后,station configuration editor配置都沒“x”
具體的組態(tài)步驟參考:
《SIMATIC NET OPC Server與S7-200/EM277的 S7連接 》:
https://www2.ad.siemens.com.cn/download/Upload/AS/application/A0303.pdf

若有收獲,就點(diǎn)個(gè)贊吧!