999久久久精品国产消防器材,国产成人久久综合77777,√最新版天堂资源网在线,精品久久久久区二区8888,卡一卡二卡三乱码视频

技成培訓(xùn)網(wǎng) 技成學(xué)習(xí)APP 技成工具箱 技成企業(yè)服務(wù)

歡迎回到技成培訓(xùn)網(wǎng)

技成培訓(xùn)網(wǎng)

電工題庫(kù)寶典

技成電工課堂

PLC練習(xí)題

技成PLC課堂

變頻器故障查詢(xún)

技成PLC學(xué)吧

伺服驅(qū)動(dòng)故障查詢(xún)

技成PLC網(wǎng)校

當(dāng)前位置:技成首頁(yè) > 文章中心 > 技成百科 > wincc OPC通訊 simatic net配置問(wèn)題

wincc OPC通訊 simatic net配置問(wèn)題

劉玉蓉 發(fā)布于2014-10-17 16:52 3 0 標(biāo)簽:

診斷提示的問(wèn)題如下:
================================ 09/21/2011 9:08:25 AM ================================
PLC Download to Current Project Selected Stations (288:91): With the set interface configuration, communication in STEP7 is not possible.
PLC Download to Current Project Selected Stations (288:47): Unable to reach the module Stationmanager via the online interface.
PLC Download to Current Project Selected Stations (13:4711): Unable to establish connection to module Stationmanager (Index 125) in station S7200.
PLC Download to Current Project Selected Stations (33:17074): Online: Driver configuration error or invalid registry parameter.
PLC Download to Current Project Selected Stations (13:4708): Unable to establish the connection to the module Stationmanager (Index 125) in station S7200.

Do you want to continue downloading without this module?
PLC Download to Current Project Selected Stations (33:17074): Online: Driver configuration error or invalid registry parameter.
PLC Download to Current Project Selected Stations (13:4708): Unable to establish the connection to the module OPC Server (Index 1) in station S7200.

Do you want to continue downloading without this module?

下面圖中總是顯示網(wǎng)卡是STOP狀態(tài),很納悶,希望各位高手幫幫忙??!

問(wèn)題補(bǔ)充:
PLC Download to Current Project Selected Stations (13:4711): Unable to establish connection to module Stationmanager (Index 125) in station S7200.
這個(gè)是什么問(wèn)題?槽125是起什么作用的?


圖片說(shuō)明: 1,錯(cuò)誤提示1   2,錯(cuò)誤提示2   3,槽號(hào)125狀態(tài)   4,station configuration editor配置  

佳答案

station configuration editor配置 上開(kāi)看組態(tài)沒(méi)有完成 :
1 ,opc sever的狀態(tài)是“X”。
2,IE general也是停止沒(méi)有連上。
組態(tài)設(shè)置都正確,下載后,station configuration editor配置都沒(méi)“x”
具體的組態(tài)步驟參考:
《SIMATIC NET OPC Server與S7-200/EM277的 S7連接 》:
https://www2.ad.siemens.com.cn/download/Upload/AS/application/A0303.pdf

若有收獲,就點(diǎn)個(gè)贊吧!

文章來(lái)源于網(wǎng)絡(luò)及文獻(xiàn)如有侵權(quán)請(qǐng)聯(lián)系站長(zhǎng)
分享到:

微信掃一掃分享

閱讀與本文標(biāo)簽相同的文章

相關(guān)推薦

最新文章 熱門(mén)文章
最新課程 免費(fèi)課程
PLC資料下載 電工電氣資料下載
應(yīng)用新秀
變頻器故障代碼查詢(xún)APP
伺服故障代碼查詢(xún)APP
技成
手機(jī)APP
熱門(mén)標(biāo)簽